| S. No. |
Description of the Test Equipment
|
Make |
Range Size |
Least Size |
Test Used |
| 1 |
Dial / digital caliper / digital & dial vernier
caliper |
Mitutoyo |
0-150 mm |
0.01 mm |
Measurement of thickness & outer Dia |
| 2 |
Micrometer digital & dial micrometer |
-Do- |
0-25 mm |
0.01 mm |
Measurement of wire dia |
| 3 |
Tensil testing machine |
KMI |
0-250 k.g.f |
100 k.g.f |
Tensile strength & Elongation |
| 4 |
Dumble cutting machine with die |
-Do- |
IS: 10810 (PT -VII) |
- |
Tensile strength & Elongation |
| 5 |
Hot air oven with thermostatic control |
Uni Tech |
0-300°C |
2°C |
Heat shock, hot deformation & shrinkage test |
| 6 |
Thermal agening oven with thermostatic control, Air
flow meter & Hour meter |
S.A Associates |
0-300°C |
1°C |
After ageing tensile strength, Elongation test &
loss of mass test |
| 7 |
Water bath with thermostatic control & hour meter
|
Uni Tech |
0-110°C |
1°C |
Water immersion A.C & D.C test insulation
resistance constant & volume resistivity test |
| 8 |
Million megaohm meter |
Shiva Nanda |
upto 10x107 mm |
1m ohm |
Insulation Resistance constant & volume
resistivity test |
| 9 |
Heat shock mandrels |
Uni Tech |
5-25 mm |
- |
heat shock test |
| 10 |
Cold bend apparatus |
-Do- |
As per IS : 10810 (PT -20) |
- |
Cold bend test |
| 11 |
Cold impact apparatus |
-Do- |
As per IS:10810 (PT-21) |
- |
cold impact test |
| 12 |
Hot deformation apparatus with weight |
-Do- |
0-850 g |
- |
Hot deformation test |
| 13 |
Travelling microscope with magnifying glass |
-Do- |
10x |
0.01m |
measurement of thickness |
| 14 |
Physical balance with weight |
Verbal |
0-211 g |
0.1 mg |
loss of mass test |
| 15 |
kelvin Double bridge with gelvanometer & D.C
source |
OSAW |
0-11 ohm |
0.2 micro ohm |
conductor resistance test |
| 16 |
Flammability apparatus with burner, stop watch &
scale |
Unitech & Sporttimer |
IS: 10810 (P-53) |
0.01sec |
Flammability test |
| 17 |
Hot set test apparatus |
Uni Tech |
0-300°C |
1°C |
Hot set test for XLPE |
| 18 |
Water absorption test |
-Do- |
0-1 Bar |
1x10-3bar |
Water absorption test for XLPE Cable |
| 19 |
Digital micro ohm meter |
Aggronic |
1M ohm to 10k ohm |
1x10-3ohm |
conductor resistance measurement |
| 20 |
Thermal stability test apparatus |
S.A Associates |
0-210°C |
0.1°C |
Thermal stability test |
| 21 |
conditioning chamber |
-Do- |
0-300°C |
1°C |
For sample conditioning |
| 22 |
Deep freezer chamber |
-Do- |
0-(-20°C) |
1°C |
For cold bend & cold impact test |
| 23 |
Standard resistance box with H.V mega ohm box |
-Do- |
0.1to 10k ohm 2 m ohm to 20 G ohm |
- |
Standared Box |
| 24 |
Digital weighing balance (Single pan) |
Dona |
0-200 gm |
0.1 mg |
Loss of mass |
| 25 |
4 cell thermal ageing oven |
Sensor india |
Sensor india |
0.1degree |
C After ageing ,tensile strength, Elongation test &
loss of mass test |
| 26 |
4.5 digit digital micro ohm meter |
Prestige electronics |
0.1(see page) |
0.1(see page) |
Conductor resistance & material purity test |
| 27 |
Oxyden index / temperature index |
Sensor india |
0-100% |
0.1% |
To check the minimum % of oxygen at which the cable
will burn like a candle in F.R.L.S. cables / to check the minimum
temperature at which the cable will lose its F.R.L.S. property |
| 28 |
Smoke density test apparatus |
S.A.associates |
0-100% |
0.1% |
To check the density of smoke generated in the fire
condition of F.R.L.S. cable |
| 29 |
Halogen test apparatus |
Unitech apparatus |
- |
- |
To check the % of halogen gas present in per unit
volume of F.R.L.S. cables |
| 30 |
Swides chimini |
Unitech apparatus |
- |
- |
o check fire resistance in fire condition of F.R.L.S.
cables |
| 31 |
Hydrolic press M/C with die |
Unitech apparatus |
- |
- |
To prepare required samples for F.R.L.S. cables and
pre testing of pre compounds |